Basic Info.
Model NO.
The D6 Series Current Transducers
Production Process
Ceramics
Application
Switching Power Supply
Customized
Non-Customized
Product Description
The D6 Series current sensor is a closed loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit, the size of primary doesn't affect test precision, no matter the location of primary in the hole of current sensor. It can really measure resolution 1000:1, it uses for precision measurement of DC, AC and pulse current.
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:15V 3:I0UT 4:NC
1. ,.(:)
When the current will be measured goes through a sensor, the current will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
2. .
Custom design in the different rated input current and the output current are available.
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
Electrical data (Ta=25 c± 5 c ) |
Type | D6-300A | D6-500A | Unit |
(Ipn) Rated current(Ipn) | ±300 | ±500 | A |
(Ip) Measure range(Ip) | 0_±500 | 0_±800 | A |
(Np/Ns) Turns ratio(Np/Ns) | 1:3000 | 1:5000 | T |
Measure resister with±15V | @±300Amax 0(min)95(max) | @±500Amax 0(min)62(max) | Ω |
@±500Amax 0(min)40(max) | @±800Amax 0(min)11(max) | Ω |
Measure resister with±18V | @±300Amax 0(min)122(max) | @±500Amax 0(min)88(max) | Ω |
@±500Amax 0(min)58(max) | @±800Amax 0(min)30(max) | Ω |
Coil resister | 31 | 50 | Ω |
Rated output | 100 | 100 | mA |
Supply voltage | ±12,±15,±18 | V |
Power Consumption | ≤20+IpX(Np/Ns) | mA |
Offset current | @Ip=0 ±0.2 | mA |
Offset drift | @ -40~+85c ≤±0.5 | mA |
Linearity | @Ip=0-±Ipn ≤0.1 | %FS |
Response time | @50A/μS, 10%-90% ≤1 | μS |
Galvanic isolation | @ 50HZ,AC,1min 6 | KV |
di/dt | >100 | A/us |
Bandwidth | @ -1dB 0~150 | KHZ |
Model | Power Supply | rated current | rated output | linearity | Mounting | window dimension | technology |
B1 | ±12V,±15V | 6-50A | 25/50mA | 0.2% | PCB | | Closed Loop |
B2 | ±12V,±15V | 5-25A | 25mA | 0.2% | PCB | | Closed Loop |
B2N | ±12V,±15V | 0.5-20A | 4V | 0.2% | PCB | | Closed Loop |
B2X | ±12V,±15V | 1-5A | 25mA | 0.2% | PCB | | Closed Loop |
B3/B3V | ±12V,±15V | 50-300A | 50/100mA | 0.2% | panel | 20.5*10 | Closed Loop |
B4 | ±12V,±15V | 200A-500A | 100mA | 0.2% | panel | 41*12 | Closed Loop |
B4X | ±12V,±15V | 200A-500A | 100mA | 0.2% | panel | 51*13 | Closed Loop |
B6 | ±12V,±15V | 50A/100A | 50mA | 0.2% | PCB | 12.5*7 | Closed Loop |
B7 | ±12V,±15V | 5-30A | 4V | 0.2% | PCB | | Closed Loop |
B8 | ±12V,±15V | 5-30A | 4V | 0.2% | PCB | | Closed Loop |
B8X | ±12V,±15V | 5-30A | 4V | 0.2% | PCB | | Closed Loop |
B8XT | +5V | 5-30A | 2.5±0.625V | 0.2% | PCB | | Closed Loop |
B9 | ±12V,±15V | 125A/200A | 125/100mA | 0.2% | PCB | 10.5*16.5 | Closed Loop |
B100 | +5V | 2-50A | 2.5±0.625V | 0.2% | PCB | 6*4 | Closed Loop |
B102T | +5V | 20A/25A | 2.5±2V | 0.2% | PCB | 8.5 | Closed Loop |
B200 | +5V | 10-40A | 2.5±1V | 0.2% | PCB | 5.5 | Closed Loop |
B201 | ±12V,±15V | 10-40A | 10--25mA | 0.2% | PCB | 5.5 | Closed Loop |
B201X | ±12V,±15V | 10-50A | 10--50mA | 0.2% | PCB | 6 | Closed Loop |
B203 | ±12V,±15V | 25-100A | 25--50mA | 0.2% | PCB | 11.5 | Closed Loop |
B203T | +12V | 10-100A | 5±2V | 0.2% | PCB | 11.5 | Closed Loop |
B203XT | +5V | 10-100A | 2.5±1V | 0.2% | PCB | 8.5 | Closed Loop |
D1 | ±12V,±15V | 50-300A | 50--150mA | 0.2% | panel | 20 | Closed Loop |
D5 | ±12V,±15V | 50-300A | 50--150mA | 0.2% | panel | 20 | Closed Loop |
D6 | ±12V,±15V | 300A/500A | 100mA | 0.2% | panel | 35 | Closed Loop |
D7 | ±12V,±15V | 1000A | 200mA | 0.2% | panel | 45 | Closed Loop |
D8 | ±12V,±15V | 1000A | 200mA | 0.2% | panel | 40 | Closed Loop |
D9 | ±12V,±15V | 2000A | 400mA | 0.2% | panel | 72 | Closed Loop |
N1 | ±12V,±15V | 10-50A | 4V | 0.2% | panel | 6.5 | Closed Loop |
C1 | ±12V,±15V | 30-500A | 4V | 1% | panel | 20 | Open Loop |
C1X | ±12V,±15V | 50-500A | 4V | 1% | panel | 28 | Open Loop |
C2 | ±12V,±15V | 30-500A | 4V | 1% | panel | 21 | Open Loop |
C2T | +12V,+15V,+24V | 50-500A | 5±2V | 1% | panel | 21 | Open Loop |
C2N | ±12V,±15V | 10-50A | 1V | 1% | panel | 8.5 | Open Loop |
C2NT | +12V | 10-50A | 2.5±1V | 1% | panel | 8.5 | Open Loop |
C3 | ±12V,±15V | 100-2000A | 4V | 1% | panel | 40.5 | Open Loop |
C5N | ±12V,±15V | 100-1000A | 4V | 1% | panel | 17.5 | Open Loop |
C5X | ±12V,±15V | 100-1000A | 4V | 1% | panel | 32 | Open Loop |
K3 | ±12V,±15V | 50-600A | 4V | 1% | panel | 20.5*10 | Open Loop |
K3N | ±12V,±15V | 30-200A | 4V | 1% | panel | 12*8 | Open Loop |
K3NT | +5V | 30-200A | 2.5±1V | 1% | panel | 12*8 | Open Loop |
K3T | +12V,+15V,+24V | 50-500A | 5±2V | 1% | panel | 20.5*10 | Open Loop |
K3X | ±12V,±15V | 50-600A | 4V | 1% | panel | 22*16 | Open Loop |
K3X3 | ±12V,±15V | 100-500A | A/B/C:4V | 1% | panel | ABC:22*13 | Open Loop |
K4 | ±12V,±15V | 100-1500A | 4V | 1% | panel | 41*12 | Open Loop |
K4N | ±12V,±15V | 100-1500A | 4V | 1% | panel | 40.5*20.5 | Open Loop |
K4X | ±12V,±15V | 200-2000A | 4V | 1% | panel | 51*13 | Open Loop |
K5 | ±12V,±15V | 500-2500A | 4V | 1% | panel | 64*16 | Open Loop |
K5N | ±12V,±15V | 200-1500A | 4V | 1% | panel | 40.5*30.5 | Open Loop |
K6 | ±12V,±15V | 500-3000A | 4V | 1% | panel | 85*27 | Open Loop |
K104 | ±12V,±15V | 1000-5000A | 4V | 1% | panel | 104*36 | Open Loop |
K140 | ±12V,±15V | 2000-10000A | 4V | 1% | panel | 140*50 | Open Loop |
K140X | ±12V,±15V | 2000-10000A | 4V | 1% | panel | 140*36 | Open Loop |
K210 | ±12V,±15V | 2000-20000A | 4V | 1% | panel | 210*100 | Open Loop |
D-C1T | +12V,+15V,+24V | DC 30-500A | DC 4V,5V | 1% | panel | 20 | Open Loop |
D-C2T | +12V,+15V,+24V | DC 30-500A | DC 4V,5V | 1% | panel | 20 | Open Loop |
D-C3T | +12V,+15V,+24V | DC 100-2000A | DC 4V,5V | 1% | panel | 40 | Open Loop |
D-K3NT | +12V,+15V,+24V | DC 30-200A | DC 4V,5V | 1% | panel | 12*8 | Open Loop |
D-K3T | +12V,+15V,+24V | DC 50-600A | DC 4V,5V | 1% | panel | 20.5*10 | Open Loop |
D-K4T | +12V,+15V,+24V | DC 100-1500A | DC 4V,5V | 1% | panel | 41*12 | Open Loop |
A-C1NT | +12V,+15V,+24V | AC 5-50A | DC 4-20mA | 1% | panel | 12 | AC&DC transducers |
A-C2 | ±12V,±15V | AC 30-500A | DC 4V,5V | 1% | panel | 21 | AC&DC transducers |
A-C2T | +12V,+15V,+24V | AC 30-500A | DC 4-20mA | 1% | panel | 21 | AC&DC transducers |
A-C3 | ±12V,±15V | AC 100-2000A | DC 4V,5V | 1% | panel | 40.5 | AC&DC transducers |
A-C3T | +12V,+15V,+24V | AC 100-2000A | DC 4-20mA | 1% | panel | 40.5 | AC&DC transducers |
A-C3X | ±12V,±15V | AC 100-2000A | DC 4V,5V | 1% | panel | 50 | AC&DC transducers |
A-K3 | ±12V,±15V | AC 30-600A | DC 4V,5V | 1% | panel | 20.5*10 | AC&DC transducers |
A-K5T | +12V,+15V,+24V | AC 200-2000A | DC 4-20mA | 1% | panel | 64*16 | AC&DC transducers |
A-N1T | +12V,+15V,+24V | AC 10-50A | DC 4-20mA | 0.5% | panel | 6.5 | AC&DC transducers |
A-D5T | +12V,+15V,+24V | AC 10-100A | DC 4-20mA | 0.5% | panel | 20 | AC&DC transducers |
A-D6T | +12V,+15V,+24V | AC 100-500A | DC 4-20mA | 0.5% | panel | 35 | AC&DC transducers |
LD1 | ±12V,±15V | DC 10-100mA | DC 5V | 1.0% | panel | 20 | Leakage CS |
LD2 | ±12V,±15V | DC 10-100mA | DC 5V | 1.0% | panel | 40 | Leakage CS |
VS1 | ±12V,±15V | 10mA | 25mA | 0.2% | PCB | | voltage Transducers |
VS2 | ±12V,±15V | 50V-800V | 20mA | 0.2% | PCB | | voltage Transducers |
VS3 | ±12V,±15V | 50V-1000V | 5V | 0.2% | | | voltage Transducers |
A-VS1TP | +12V,+15V,+24V | AC 50V-800V | DC 20mA | 0.2% | | | voltage Transducers |
A-VS2 | ±12V,±15V | AC 50V-800V | DC 20mA | 0.2% | PCB | | voltage Transducers |
Address:
Room 1403 Tower a, No. 4, Shashan Road, Jiangyin, Wuxi, Jiangsu, China
Business Type:
Manufacturer/Factory, Group Corporation
Business Range:
Computer Products, Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001, QC 080000
Company Introduction:
Since established, Powerway recently became a world leading corporation in field of Split core (Clamp on) type of current sensor and Clamp-on Rogowski coil. Powerway will be grown as a global leader to develop various part range for transportation in smart grid electric industry, high qualified current measuring sensor, track industry, electric vehicle and lift industry with customer satisfaction.
Powerway Electrical is a global leader to manufacture current and voltage sensor in smart grid industry all covering of distribution, saving, protecting and metering electricity.
As current sensing expert, Powerway builds up additionally Wi-GEM and Multi-GEM measuring system with high accuracy sensor technology to make power distribution monitoring effectively.
Powerway is a creative corporation who always thinks what will be unique, innovative and stable.
Powerway establishes highly qualified production availability and speedy designing capability for power and current monitoring. Powerway′ S best staffs always offer optimized solution for customer satisfaction.