Basic Info.
Model NO.
CX5 Current Transducers
Output Signal Type
Analog Output
Production Process
Integration
Application
Switching Power Supply
Customized
Non-Customized
Product Description
C5X series hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
Features:
Closed loop (compensated) multi-rang current transducer using the Hall effect
Unipolar voltage supply
Compact design for PCB mounting
Incorporated measuing resistance
Extended measuing range
Advantages
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external interference
Current overload capability
Applications:
· Variable speed drives
· Welding machine
· Battery supplied applications
· Uninterruptible Power Supplies (UPS)
· Electrochemical
Directions for use:
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end. (Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.
Standards
· UL94-V0.
· EN60947-1: 2004
· IEC60950-1: 2001
· EN50178: 1998
· SJ 20790-2000
Model | Power Supply | rated current | rated output | linearity | Mounting | window dimension | technology |
B1 | ±12V,±15V | 6-50A | 25/50mA | 0.2% | PCB | | Closed Loop |
B2 | ±12V,±15V | 5-25A | 25mA | 0.2% | PCB | | Closed Loop |
B2N | ±12V,±15V | 0.5-20A | 4V | 0.2% | PCB | | Closed Loop |
B2X | ±12V,±15V | 1-5A | 25mA | 0.2% | PCB | | Closed Loop |
B3/B3V | ±12V,±15V | 50-300A | 50/100mA | 0.2% | panel | 20.5*10 | Closed Loop |
B4 | ±12V,±15V | 200A-500A | 100mA | 0.2% | panel | 41*12 | Closed Loop |
B4X | ±12V,±15V | 200A-500A | 100mA | 0.2% | panel | 51*13 | Closed Loop |
B6 | ±12V,±15V | 50A/100A | 50mA | 0.2% | PCB | 12.5*7 | Closed Loop |
B7 | ±12V,±15V | 5-30A | 4V | 0.2% | PCB | | Closed Loop |
B8 | ±12V,±15V | 5-30A | 4V | 0.2% | PCB | | Closed Loop |
B8X | ±12V,±15V | 5-30A | 4V | 0.2% | PCB | | Closed Loop |
B8XT | +5V | 5-30A | 2.5±0.625V | 0.2% | PCB | | Closed Loop |
B9 | ±12V,±15V | 125A/200A | 125/100mA | 0.2% | PCB | 10.5*16.5 | Closed Loop |
B100 | +5V | 2-50A | 2.5±0.625V | 0.2% | PCB | 6*4 | Closed Loop |
B102T | +5V | 20A/25A | 2.5±2V | 0.2% | PCB | 8.5 | Closed Loop |
B200 | +5V | 10-40A | 2.5±1V | 0.2% | PCB | 5.5 | Closed Loop |
B201 | ±12V,±15V | 10-40A | 10--25mA | 0.2% | PCB | 5.5 | Closed Loop |
B201X | ±12V,±15V | 10-50A | 10--50mA | 0.2% | PCB | 6 | Closed Loop |
B203 | ±12V,±15V | 25-100A | 25--50mA | 0.2% | PCB | 11.5 | Closed Loop |
B203T | +12V | 10-100A | 5±2V | 0.2% | PCB | 11.5 | Closed Loop |
B203XT | +5V | 10-100A | 2.5±1V | 0.2% | PCB | 8.5 | Closed Loop |
D1 | ±12V,±15V | 50-300A | 50--150mA | 0.2% | panel | 20 | Closed Loop |
D5 | ±12V,±15V | 50-300A | 50--150mA | 0.2% | panel | 20 | Closed Loop |
D6 | ±12V,±15V | 300A/500A | 100mA | 0.2% | panel | 35 | Closed Loop |
D7 | ±12V,±15V | 1000A | 200mA | 0.2% | panel | 45 | Closed Loop |
D8 | ±12V,±15V | 1000A | 200mA | 0.2% | panel | 40 | Closed Loop |
D9 | ±12V,±15V | 2000A | 400mA | 0.2% | panel | 72 | Closed Loop |
N1 | ±12V,±15V | 10-50A | 4V | 0.2% | panel | 6.5 | Closed Loop |
C1 | ±12V,±15V | 30-500A | 4V | 1% | panel | 20 | Open Loop |
C1X | ±12V,±15V | 50-500A | 4V | 1% | panel | 28 | Open Loop |
C2 | ±12V,±15V | 30-500A | 4V | 1% | panel | 21 | Open Loop |
C2T | +12V,+15V,+24V | 50-500A | 5±2V | 1% | panel | 21 | Open Loop |
C2N | ±12V,±15V | 10-50A | 1V | 1% | panel | 8.5 | Open Loop |
C2NT | +12V | 10-50A | 2.5±1V | 1% | panel | 8.5 | Open Loop |
C3 | ±12V,±15V | 100-2000A | 4V | 1% | panel | 40.5 | Open Loop |
C5N | ±12V,±15V | 100-1000A | 4V | 1% | panel | 17.5 | Open Loop |
C5X | ±12V,±15V | 100-1000A | 4V | 1% | panel | 32 | Open Loop |
K3 | ±12V,±15V | 50-600A | 4V | 1% | panel | 20.5*10 | Open Loop |
K3N | ±12V,±15V | 30-200A | 4V | 1% | panel | 12*8 | Open Loop |
K3NT | +5V | 30-200A | 2.5±1V | 1% | panel | 12*8 | Open Loop |
K3T | +12V,+15V,+24V | 50-500A | 5±2V | 1% | panel | 20.5*10 | Open Loop |
K3X | ±12V,±15V | 50-600A | 4V | 1% | panel | 22*16 | Open Loop |
K3X3 | ±12V,±15V | 100-500A | A/B/C:4V | 1% | panel | ABC:22*13 | Open Loop |
K4 | ±12V,±15V | 100-1500A | 4V | 1% | panel | 41*12 | Open Loop |
K4N | ±12V,±15V | 100-1500A | 4V | 1% | panel | 40.5*20.5 | Open Loop |
K4X | ±12V,±15V | 200-2000A | 4V | 1% | panel | 51*13 | Open Loop |
K5 | ±12V,±15V | 500-2500A | 4V | 1% | panel | 64*16 | Open Loop |
K5N | ±12V,±15V | 200-1500A | 4V | 1% | panel | 40.5*30.5 | Open Loop |
K6 | ±12V,±15V | 500-3000A | 4V | 1% | panel | 85*27 | Open Loop |
K104 | ±12V,±15V | 1000-5000A | 4V | 1% | panel | 104*36 | Open Loop |
K140 | ±12V,±15V | 2000-10000A | 4V | 1% | panel | 140*50 | Open Loop |
K140X | ±12V,±15V | 2000-10000A | 4V | 1% | panel | 140*36 | Open Loop |
K210 | ±12V,±15V | 2000-20000A | 4V | 1% | panel | 210*100 | Open Loop |
D-C1T | +12V,+15V,+24V | DC 30-500A | DC 4V,5V | 1% | panel | 20 | Open Loop |
D-C2T | +12V,+15V,+24V | DC 30-500A | DC 4V,5V | 1% | panel | 20 | Open Loop |
D-C3T | +12V,+15V,+24V | DC 100-2000A | DC 4V,5V | 1% | panel | 40 | Open Loop |
D-K3NT | +12V,+15V,+24V | DC 30-200A | DC 4V,5V | 1% | panel | 12*8 | Open Loop |
D-K3T | +12V,+15V,+24V | DC 50-600A | DC 4V,5V | 1% | panel | 20.5*10 | Open Loop |
D-K4T | +12V,+15V,+24V | DC 100-1500A | DC 4V,5V | 1% | panel | 41*12 | Open Loop |
A-C1NT | +12V,+15V,+24V | AC 5-50A | DC 4-20mA | 1% | panel | 12 | AC&DC transducers |
A-C2 | ±12V,±15V | AC 30-500A | DC 4V,5V | 1% | panel | 21 | AC&DC transducers |
A-C2T | +12V,+15V,+24V | AC 30-500A | DC 4-20mA | 1% | panel | 21 | AC&DC transducers |
A-C3 | ±12V,±15V | AC 100-2000A | DC 4V,5V | 1% | panel | 40.5 | AC&DC transducers |
A-C3T | +12V,+15V,+24V | AC 100-2000A | DC 4-20mA | 1% | panel | 40.5 | AC&DC transducers |
A-C3X | ±12V,±15V | AC 100-2000A | DC 4V,5V | 1% | panel | 50 | AC&DC transducers |
A-K3 | ±12V,±15V | AC 30-600A | DC 4V,5V | 1% | panel | 20.5*10 | AC&DC transducers |
A-K5T | +12V,+15V,+24V | AC 200-2000A | DC 4-20mA | 1% | panel | 64*16 | AC&DC transducers |
A-N1T | +12V,+15V,+24V | AC 10-50A | DC 4-20mA | 0.5% | panel | 6.5 | AC&DC transducers |
A-D5T | +12V,+15V,+24V | AC 10-100A | DC 4-20mA | 0.5% | panel | 20 | AC&DC transducers |
A-D6T | +12V,+15V,+24V | AC 100-500A | DC 4-20mA | 0.5% | panel | 35 | AC&DC transducers |
LD1 | ±12V,±15V | DC 10-100mA | DC 5V | 1.0% | panel | 20 | Leakage CS |
LD2 | ±12V,±15V | DC 10-100mA | DC 5V | 1.0% | panel | 40 | Leakage CS |
VS1 | ±12V,±15V | 10mA | 25mA | 0.2% | PCB | | voltage Transducers |
VS2 | ±12V,±15V | 50V-800V | 20mA | 0.2% | PCB | | voltage Transducers |
VS3 | ±12V,±15V | 50V-1000V | 5V | 0.2% | | | voltage Transducers |
A-VS1TP | +12V,+15V,+24V | AC 50V-800V | DC 20mA | 0.2% | | | voltage Transducers |
A-VS2 | ±12V,±15V | AC 50V-800V | DC 20mA | 0.2% | PCB | | voltage Transducers |
Address:
Room 1403 Tower a, No. 4, Shashan Road, Jiangyin, Wuxi, Jiangsu, China
Business Type:
Manufacturer/Factory, Group Corporation
Business Range:
Computer Products, Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001, QC 080000
Company Introduction:
Since established, Powerway recently became a world leading corporation in field of Split core (Clamp on) type of current sensor and Clamp-on Rogowski coil. Powerway will be grown as a global leader to develop various part range for transportation in smart grid electric industry, high qualified current measuring sensor, track industry, electric vehicle and lift industry with customer satisfaction.
Powerway Electrical is a global leader to manufacture current and voltage sensor in smart grid industry all covering of distribution, saving, protecting and metering electricity.
As current sensing expert, Powerway builds up additionally Wi-GEM and Multi-GEM measuring system with high accuracy sensor technology to make power distribution monitoring effectively.
Powerway is a creative corporation who always thinks what will be unique, innovative and stable.
Powerway establishes highly qualified production availability and speedy designing capability for power and current monitoring. Powerway′ S best staffs always offer optimized solution for customer satisfaction.