Basic Info.
Output Signal Type
Analog Output
Production Process
SemiConductor Integrated
Application
Switching Power Supply
Customized
Non-Customized
Product Description
Hall Effect Open Loop Current Sensor is a current measurement device which develop on base of the hall effect principle, it can accurately measure DC, AC, pulsed current in isolation way.
Principle: Hall Effect Open Loop Current Sensor develops on base of open loop operation principle. Primary Current IP produce a magnetic field thanks to the air gap of magnetic core, open loop current sensor amplify the Hall generator voltage to provide an output voltage, this also known as direct measurement.
Features: Low insertion loss, Space saving, High accuracy, Low-cost sensing product, Fast response time
Applications: Widely used in servo drive, variable frequency drive, DC Panel, Motor Control, HVAC, over current protection and current monitoring of electronic circuits.
Model | Power Supply | rated current | rated output | linearity | Mounting | window dimension | technology |
B1 | ±12V,±15V | 6-50A | 25/50mA | 0.2% | PCB | | Closed Loop |
B2 | ±12V,±15V | 5-25A | 25mA | 0.2% | PCB | | Closed Loop |
B2N | ±12V,±15V | 0.5-20A | 4V | 0.2% | PCB | | Closed Loop |
B2X | ±12V,±15V | 1-5A | 25mA | 0.2% | PCB | | Closed Loop |
B3/B3V | ±12V,±15V | 50-300A | 50/100mA | 0.2% | panel | 20.5*10 | Closed Loop |
B4 | ±12V,±15V | 200A-500A | 100mA | 0.2% | panel | 41*12 | Closed Loop |
B4X | ±12V,±15V | 200A-500A | 100mA | 0.2% | panel | 51*13 | Closed Loop |
B6 | ±12V,±15V | 50A/100A | 50mA | 0.2% | PCB | 12.5*7 | Closed Loop |
B7 | ±12V,±15V | 5-30A | 4V | 0.2% | PCB | | Closed Loop |
B8 | ±12V,±15V | 5-30A | 4V | 0.2% | PCB | | Closed Loop |
B8X | ±12V,±15V | 5-30A | 4V | 0.2% | PCB | | Closed Loop |
B8XT | +5V | 5-30A | 2.5±0.625V | 0.2% | PCB | | Closed Loop |
B9 | ±12V,±15V | 125A/200A | 125/100mA | 0.2% | PCB | 10.5*16.5 | Closed Loop |
B100 | +5V | 2-50A | 2.5±0.625V | 0.2% | PCB | 6*4 | Closed Loop |
B102T | +5V | 20A/25A | 2.5±2V | 0.2% | PCB | 8.5 | Closed Loop |
B200 | +5V | 10-40A | 2.5±1V | 0.2% | PCB | 5.5 | Closed Loop |
B201 | ±12V,±15V | 10-40A | 10--25mA | 0.2% | PCB | 5.5 | Closed Loop |
B201X | ±12V,±15V | 10-50A | 10--50mA | 0.2% | PCB | 6 | Closed Loop |
B203 | ±12V,±15V | 25-100A | 25--50mA | 0.2% | PCB | 11.5 | Closed Loop |
B203T | +12V | 10-100A | 5±2V | 0.2% | PCB | 11.5 | Closed Loop |
B203XT | +5V | 10-100A | 2.5±1V | 0.2% | PCB | 8.5 | Closed Loop |
D1 | ±12V,±15V | 50-300A | 50--150mA | 0.2% | panel | 20 | Closed Loop |
D5 | ±12V,±15V | 50-300A | 50--150mA | 0.2% | panel | 20 | Closed Loop |
D6 | ±12V,±15V | 300A/500A | 100mA | 0.2% | panel | 35 | Closed Loop |
D7 | ±12V,±15V | 1000A | 200mA | 0.2% | panel | 45 | Closed Loop |
D8 | ±12V,±15V | 1000A | 200mA | 0.2% | panel | 40 | Closed Loop |
D9 | ±12V,±15V | 2000A | 400mA | 0.2% | panel | 72 | Closed Loop |
N1 | ±12V,±15V | 10-50A | 4V | 0.2% | panel | 6.5 | Closed Loop |
C1 | ±12V,±15V | 30-500A | 4V | 1% | panel | 20 | Open Loop |
C1X | ±12V,±15V | 50-500A | 4V | 1% | panel | 28 | Open Loop |
C2 | ±12V,±15V | 30-500A | 4V | 1% | panel | 21 | Open Loop |
C2T | +12V,+15V,+24V | 50-500A | 5±2V | 1% | panel | 21 | Open Loop |
C2N | ±12V,±15V | 10-50A | 1V | 1% | panel | 8.5 | Open Loop |
C2NT | +12V | 10-50A | 2.5±1V | 1% | panel | 8.5 | Open Loop |
C3 | ±12V,±15V | 100-2000A | 4V | 1% | panel | 40.5 | Open Loop |
C5N | ±12V,±15V | 100-1000A | 4V | 1% | panel | 17.5 | Open Loop |
C5X | ±12V,±15V | 100-1000A | 4V | 1% | panel | 32 | Open Loop |
K3 | ±12V,±15V | 50-600A | 4V | 1% | panel | 20.5*10 | Open Loop |
K3N | ±12V,±15V | 30-200A | 4V | 1% | panel | 12*8 | Open Loop |
K3NT | +5V | 30-200A | 2.5±1V | 1% | panel | 12*8 | Open Loop |
K3T | +12V,+15V,+24V | 50-500A | 5±2V | 1% | panel | 20.5*10 | Open Loop |
K3X | ±12V,±15V | 50-600A | 4V | 1% | panel | 22*16 | Open Loop |
K3X3 | ±12V,±15V | 100-500A | A/B/C:4V | 1% | panel | ABC:22*13 | Open Loop |
K4 | ±12V,±15V | 100-1500A | 4V | 1% | panel | 41*12 | Open Loop |
K4N | ±12V,±15V | 100-1500A | 4V | 1% | panel | 40.5*20.5 | Open Loop |
K4X | ±12V,±15V | 200-2000A | 4V | 1% | panel | 51*13 | Open Loop |
K5 | ±12V,±15V | 500-2500A | 4V | 1% | panel | 64*16 | Open Loop |
K5N | ±12V,±15V | 200-1500A | 4V | 1% | panel | 40.5*30.5 | Open Loop |
K6 | ±12V,±15V | 500-3000A | 4V | 1% | panel | 85*27 | Open Loop |
K104 | ±12V,±15V | 1000-5000A | 4V | 1% | panel | 104*36 | Open Loop |
K140 | ±12V,±15V | 2000-10000A | 4V | 1% | panel | 140*50 | Open Loop |
K140X | ±12V,±15V | 2000-10000A | 4V | 1% | panel | 140*36 | Open Loop |
K210 | ±12V,±15V | 2000-20000A | 4V | 1% | panel | 210*100 | Open Loop |
D-C1T | +12V,+15V,+24V | DC 30-500A | DC 4V,5V | 1% | panel | 20 | Open Loop |
D-C2T | +12V,+15V,+24V | DC 30-500A | DC 4V,5V | 1% | panel | 20 | Open Loop |
D-C3T | +12V,+15V,+24V | DC 100-2000A | DC 4V,5V | 1% | panel | 40 | Open Loop |
D-K3NT | +12V,+15V,+24V | DC 30-200A | DC 4V,5V | 1% | panel | 12*8 | Open Loop |
D-K3T | +12V,+15V,+24V | DC 50-600A | DC 4V,5V | 1% | panel | 20.5*10 | Open Loop |
D-K4T | +12V,+15V,+24V | DC 100-1500A | DC 4V,5V | 1% | panel | 41*12 | Open Loop |
A-C1NT | +12V,+15V,+24V | AC 5-50A | DC 4-20mA | 1% | panel | 12 | AC&DC transducers |
A-C2 | ±12V,±15V | AC 30-500A | DC 4V,5V | 1% | panel | 21 | AC&DC transducers |
A-C2T | +12V,+15V,+24V | AC 30-500A | DC 4-20mA | 1% | panel | 21 | AC&DC transducers |
A-C3 | ±12V,±15V | AC 100-2000A | DC 4V,5V | 1% | panel | 40.5 | AC&DC transducers |
A-C3T | +12V,+15V,+24V | AC 100-2000A | DC 4-20mA | 1% | panel | 40.5 | AC&DC transducers |
A-C3X | ±12V,±15V | AC 100-2000A | DC 4V,5V | 1% | panel | 50 | AC&DC transducers |
A-K3 | ±12V,±15V | AC 30-600A | DC 4V,5V | 1% | panel | 20.5*10 | AC&DC transducers |
A-K5T | +12V,+15V,+24V | AC 200-2000A | DC 4-20mA | 1% | panel | 64*16 | AC&DC transducers |
A-N1T | +12V,+15V,+24V | AC 10-50A | DC 4-20mA | 0.5% | panel | 6.5 | AC&DC transducers |
A-D5T | +12V,+15V,+24V | AC 10-100A | DC 4-20mA | 0.5% | panel | 20 | AC&DC transducers |
A-D6T | +12V,+15V,+24V | AC 100-500A | DC 4-20mA | 0.5% | panel | 35 | AC&DC transducers |
LD1 | ±12V,±15V | DC 10-100mA | DC 5V | 1.0% | panel | 20 | Leakage CS |
LD2 | ±12V,±15V | DC 10-100mA | DC 5V | 1.0% | panel | 40 | Leakage CS |
VS1 | ±12V,±15V | 10mA | 25mA | 0.2% | PCB | | voltage Transducers |
VS2 | ±12V,±15V | 50V-800V | 20mA | 0.2% | PCB | | voltage Transducers |
VS3 | ±12V,±15V | 50V-1000V | 5V | 0.2% | | | voltage Transducers |
A-VS1TP | +12V,+15V,+24V | AC 50V-800V | DC 20mA | 0.2% | | | voltage Transducers |
A-VS2 | ±12V,±15V | AC 50V-800V | DC 20mA | 0.2% | PCB | | voltage Transducers |
Address:
Room 1403 Tower a, No. 4, Shashan Road, Jiangyin, Wuxi, Jiangsu, China
Business Type:
Manufacturer/Factory, Group Corporation
Business Range:
Computer Products, Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001, QC 080000
Company Introduction:
Since established, Powerway recently became a world leading corporation in field of Split core (Clamp on) type of current sensor and Clamp-on Rogowski coil. Powerway will be grown as a global leader to develop various part range for transportation in smart grid electric industry, high qualified current measuring sensor, track industry, electric vehicle and lift industry with customer satisfaction.
Powerway Electrical is a global leader to manufacture current and voltage sensor in smart grid industry all covering of distribution, saving, protecting and metering electricity.
As current sensing expert, Powerway builds up additionally Wi-GEM and Multi-GEM measuring system with high accuracy sensor technology to make power distribution monitoring effectively.
Powerway is a creative corporation who always thinks what will be unique, innovative and stable.
Powerway establishes highly qualified production availability and speedy designing capability for power and current monitoring. Powerway′ S best staffs always offer optimized solution for customer satisfaction.